Single Phase
Ventilated: Series 35: .050 kVA - .750 kVA - Series 80: 1.0 kVA -
5.0 kVA
UL Listed, File E3210.
CSA Listed, File LR 560
Double wound isolation-type transformer
Copper windings and copper lead wire terminations
used throughout.
NEMA-3R, wall mount enclosure suitable for indoor
or outdoor use. May be used in banks of 2 or 3
units for standard three phase voltages and
nonstandard, open delta auto-transformer
applications. (Note: .050 kVA - .100 kVA are in a
NEMA-1 enclosure)
|

*Nonstandard designs are
available by consulting us.
|
Single Phase
Encapsulated:
Series 85 ISO-Shield: .250 kVA - 25 kVA
UL Listed, File E3210, .250 - 10 kVA
UL Listed, File E78234, 15 - 25 kVA
Double
wound isolation-type transformer
Copper
windings and copper lead wire terminations used throughout.
Electrostatic
shield between primary and secondary windings provides cleaner
output voltage and helps to reduce spikes and transients.
Epoxy-silica
encapsulated core and coil provides a transformer particularly well
suited for harsh commercial and industrial applications.
NEMA-3R,
wall mount enclosure suitable for indoor or outdoor use. May be used
in banks of 2 or 3 units for standard three phase voltages and
nonstandard, open delta autotransformer applications.
|
|
Single Phase
Cabinet Style
Series 61 ISO-Shield: 7.5 kVA - 100 kVA
UL Listed, File
E78234
CUL Listed
through UL File E3210
Double
wound, isolation type transformers
Aluminum
windings connect to bus bar style terminations equipped with NEMA
standard holes for compression style or ring terminals
NEMA-3R,
ventilated, cabinet style, floor mount enclosure suitable for indoor
or outdoor use.
No extra rainshields required for outdoor use. May
also be used in banks of 2 or 3 units for three phase isolation or
autotransformer applications
Electrostatic
shield between primary and secondary windings provides cleaner
output voltage and helps to reduce spikes and transients.
Vibration
dampening pads provide quiet operation
Wall Mounting brackets are available in sizes up to 50 kVA
Core and coil and nonstandard designs are available by consulting
us.
| Primary |
Secondary |
| 240
X 480 |
120
/ 240 |
| 240
X 480 |
120
- Fused |
| 480 |
120 / 240 |
| 208 |
120 / 240 |
| 277 |
120
/ 240 |
| 600 |
120
/ 240 |
| 120 / 240 |
120 / 240 |
| 120 / 240 |
12 / 24 |
| 120 / 240 |
16 / 32 |
| 240 / 480 |
24 / 48 |
|

|
CE Marked Single Phase Encapsulated
Series ES - 11 .250 kVA - 25 kVA
Series ES Single Phase Encapsulated
Transformers are designed to comply with Domestic, North American,
and European Union electrical and testing standards. Series ES are
UL and Canadian UL Listed by Underwriters Labs. In addition, Series
ES are CE Marked, and licensed by the German testing agency TÜV
Rheinland under License Number R 2679035.01.
Series ES transformers are the answer to your export needs. With the
voltage combinations listed below, and built In approvals, the ES
Series provide no-nonsense solutions for equipment destined for the
European Community of nations.
Under EC guidelines, connecting transformers to line end load
require finger safe connections. While other manufacturers provide
leads, Dongan provides finger safe terminals on all ES- 11
transformers. This feature eliminates the necessity of a difficult,
labor intensive installation of terminals in the wiring compartment
by the end user
The voltage combinations offered represent some of the most
universally used. However and combination of primary and secondary
incorporating voltages of 600 volts and below is available on a
short lead time, special order basis. In addition, capacities up to
25 kVA and special temperature rise configurations can be furnished.
Please consult your distributor, Dongan Representative or the
factory for special ES Series transformer requirements.
CE
Marked
TÜV Rheinland
Licensed, R 9679035.01
UL
Listed, File E3210
CSA Listed thru UL, File E3210
NEMA 12, IP54 enclosure.
All copper windings.
IEC type finger safe terminals.
200° C (H) Insulation System.
50/60 Hertz.
Class 1, general use, isolating transformer.
All
Series ES are provided with an electrostatic shield (earth metal
screen)
All Series ES are provided with an color coded protective earth (PE)
terminal.
Consult factory for desired voltage combinations and kVA sizes not
listed.
| Primary |
Secondary |
| 380
/ 400 / 416 / 440 / 460 / 480 / 575 |
110
/ 115 / 120 |
| 220
/ 380 / 400 / 416 |
120
/ 240 |
|
|